Technical data |
|
|
|
General |
|
|
|
Maximum voltage between terminal and ground |
|
|
AC |
1000 V |
|
|
DC |
1500 V |
|
|
Batteries |
2 AA IEC LR6 alkaline batteries |
|
|
Display |
Dual, illuminated display |
|
|
Automatyczne wyłączanie zasilania |
After 20 min |
|
|
Electric |
|
|
|
Accuracy |
|
|
|
Accuracy is valid for 1 year after calibration, for an operating temperature of 18 ° C to 28 ° C and a relative humidity of 0 to 75%. Accuracy data takes the form: ± ([% reading] + [number of least significant digits]). |
Temperature coefficients |
Add 0.1 × given accuracy for each degree C above 28 ° C or below 18 ° C |
AC Current: Jaw |
|
|
|
Range |
999,9 A |
|
|
Resolution |
0,1 A |
|
|
Accuracy |
2% + 5 digits (10 Hz to 100 Hz) |
|
|
2.5% + 5 digits (100 Hz to 500 Hz) |
|
Crest Factor (50/60 Hz) |
2.5 at 600.0 amps |
|
|
|
3.0 at 500.0 A |
|
|
|
1.42 at 999.9A |
|
|
|
Additional 2% for crest factor >2 |
|
|
Additional 2% for crest factor >2 |
|
|
|
Range |
999,9 A |
|
|
|
2500 A |
|
|
Resolution |
0,1 A (≤999,9 A) |
|
|
|
1 A (≤2500 A) |
|
|
Accuracy |
3% of reading + 5 digits (10 to 500 Hz) |
|
Crest Factor (50/60 Hz) |
2.5 at 1400 amps |
|
|
|
3.0 at 1100 amps |
|
|
|
1.42 at 2500 amps |
|
|
|
Additional 2% for crest factor >2 |
|
|
Sensitivity depending on the position |
|
|
|
 |
Distance from the optimal point |
i2500-10 Flex |
i2500-18 Flex |
Błąd |
A |
12,7 mm |
35,6 mm |
±0,5% |
B |
20,3 mm |
50,8 mm |
±1,0% |
C |
35,6 mm |
63,5 mm |
±2,0% |
The measurement uncertainty was given assuming the central position of the primary conductor in the optimal position, the absence of an external electric and magnetic field, and operation within the recommended operating temperatures. |
|
|
|
|
DC Current |
|
|
|
Range |
999,9 A |
|
|
Resolution |
0,1 A |
|
|
Accuracy |
2% of reading + 5 digits[1] |
|
|
|
[1]When using the ZERO (B) function to compensate for offsets. |
AC Voltage |
|
|
|
Range |
600,0 V |
|
|
|
1000 V |
|
|
Resolution |
0,1 V (≤600,0 V) |
|
|
|
1 V (≤1000 V) |
|
|
Accuracy |
1% of reading + 5 digits (20 Hz to 500 Hz) |
|
DC voltage |
|
|
|
Range |
600,0 V |
|
|
|
1500 V |
|
|
Resolution |
0,1 V (≤600,0 V) |
|
|
|
1 V (≤1500 V) |
|
|
Accuracy |
1% reading + 5 digits |
|
|
mV DC |
|
|
|
Range |
500,0 mV |
|
|
Resolution |
0,1 mV |
|
|
Accuracy |
1% reading + 5 digits |
|
|
Częstotliwość prądu: Szczęka |
|
|
|
Range |
Od 5,0 Hz do 500,0 Hz |
|
|
Resolution |
0,1 Hz |
|
|
Accuracy |
0.5% reading + 5 digits |
|
|
Trigger level |
od 5 Hz do 10 Hz, ≥10 A |
|
|
|
od 10 Hz do 100 Hz, ≥5 A |
|
|
|
od 100 Hz do 500 Hz, ≥10 A |
|
|
Current frequency: Flexible current probe |
|
|
|
Range |
Od 5,0 Hz do 500,0 Hz |
|
|
Resolution |
0,1 Hz |
|
|
Accuracy |
0.5% reading + 5 digits |
|
|
Trigger level |
od 5 Hz do 20 Hz, ≥25 A |
|
|
|
od 20 Hz do 100 Hz, ≥20 A |
|
|
|
od 100 Hz do 500 Hz, ≥25 A |
|
|
Voltage frequency |
|
|
|
Range |
Od 5,0 Hz do 500,0 Hz |
|
|
Resolution |
0,1 Hz |
|
|
Accuracy |
0.5% reading + 5 digits |
|
|
Trigger level |
od 5 Hz do 20 Hz, ≥5 V |
|
|
|
od 20 Hz do 100 Hz, ≥5 V |
|
|
|
od 100 Hz do 500 Hz, ≥10 V |
|
|
Moc, prąd stały (DC) |
|
|
|
Range |
600,0 kVA (range 600,0 V DC) |
|
|
|
1500 kVA (range 1500 V DC) |
|
|
Resolution |
0,1 kVA |
|
|
|
1 kVA |
|
|
Accuracy |
2% of reading + 2.0 kVA |
|
|
|
2% of reading + 20 kVA |
|
|
Rezystancja |
|
|
|
Range |
600,0 Ω |
|
|
|
6000 Ω |
|
|
|
60,00 kΩ |
|
|
Resolution |
0,1 Ω (≤600,0 Ω) |
|
|
|
1 Ω (≤6000 Ω) |
|
|
|
0,01 kΩ (≤60,00 kΩ) |
|
|
Accuracy |
1% reading + 5 digits |
|
|
Capacity |
|
|
|
Range |
100,0 μF |
|
|
|
1000 μF |
|
|
Resolution |
0,1 μF (≤100,0 μF) |
|
|
|
1 μF (≤1000 μF) |
|
|
Accuracy |
1% reading + 5 digits |
|
|
Trigger level for inrush current |
5 A |
|
|
Mechanical parameters |
|
|
|
Dimensions (L x W x H) |
281 mm x 84 mm x 49 mm |
|
|
Weight (with batteries) |
520 g |
|
|
Jaw opening |
34 mm |
|
|
Flexible current probe diameter |
7,5 mm |
|
|
Flexible current probe cable length |
|
|
|
(from the head to the electronic connector) |
1,8 m |
|
|
Environmental parameters |
|
|
|
Operating temperature |
od -10°C do 50°C |
|
|
Storage temperature |
od -40°C do 60°C |
|
|
Operating humidity |
No condensation (≤10°C) |
|
|
|
≤ 90% relative humidity (at a temperature of 10 to 30 ° C) |
|
|
|
≤ 75% relative humidity (at a temperature of 30 to 40 ° C) |
|
|
|
≤ 45% relative humidity (at a temperature of 40 to 50 ° C) |
|
|
Operating altitude (above sea level) |
2000 m |
|
|
Storage height |
12 000 m |
|
|
Protection class (IP) |
IEC 60529: IP54, instrument off |
|
|
Electromagnetic Compatibility (EMC) |
|
|
|
International |
IEC 61326-1: Portable Device, Electromagnetic Environment, IEC 61326-2-2, CISPR 11: Group 1, Class A |
|
Group 1: Equipment intentionally generates and / or uses radio frequency energy, transmitted through conductive elements, that is necessary for the internal operation of the equipment itself. |
Class A: The device can be used in all installations except for residential installations and installations connected directly to the low-voltage network supplying residential buildings. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. |
Caution: This instrument is not intended for use in residential environments and may not provide adequate protection for RF reception in such environments. |
Korea (KCC) |
Class A equipment (industrial broadcasting and communication equipment) |
|
Class A: The device complies with the standards for industrial electromagnetic equipment that both the seller and the operator should be aware of. This appliance is intended for professional use and should not be used for domestic use. |
USA (FCC) |
Under 47 CFR 15 subpart B, this device is considered exempt under clause 15.103. |
Security |
|
|
|
General information |
IEC 61010-1, pollution degree 2 |
|
Measurement |
IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V |
|
|
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V |
|
Wireless communication module |
|
|
|
Radio frequency certification |
FCC ID: T68-FBLE, IC: 6627A-FBLE |
|
Radio frequency range for wireless communication |
Od 2400 MHz do 2483,5 MHz |
|
|
Output power |
<100 mW |
|
|
SIMPLIFIED EU DECLARATION OF CONFORMITY |
|
|
Hereby, Fluke declares that the radio equipment contained in this product is in compliance with Directive 2014/53 / EU. |
The full text of the EU declaration of conformity is available at the following internet address: |
|
|
www.fluke.com/en-us/declaration-of-conformity |
|